DHN - HEPA diffuser

HEPA nozzle diffuser
High turbulent nozzle diffuser with HEPA filter for hospital and clean room environments to be installed flush to the ceiling or to the wall.
- Radial or swirl air supply through adjustable nozzle
- Available for supply and exhaust
- Suitable for integrated ceiling and wall installation
- A measurement access through the diffuser plenum for pressure measurement and aerosol test
- Easy filter change and cleaning through the openable diffuser panel
- Reduced installation space requirement due to low unit height
- Easy installation with fixing brackets
- Sizes 595 and 670 adapted for installation in modular suspended ceilings
- Filters E10, H13 and H14 available as standard
- Powder coated finishing, standard colour RAL9010
Accessories
- E10 and H13 with foamed polyurethane gasket
- H14 with foamed polyurthane or gel gasket
- Pre-filter G4 for exhaust applications
- Filters do not include to the diffuser delivery, to be ordered separately
Halton terminal diffuser DHN with HEPA filter for hospital and clean room environments to be installed flush to the ceiling or to the wall. Air is supplied through individually adjustable nozzles.
Nominal size 595 and 670 adapted for installation in modular suspended ceiling. Diffuser frame (size 595) adapted to suite different ceiling types. The diffuser is installed either fast into ceiling/wall or hanged from the ceiling using movable fixing parts.
Diffuser casing is made of galvanized steel and powder painted. The inside of the diffuser is smooth to enable easy cleaning and free from grooves to prevent collection of impurities. Plenum is equipped with an internal measurement tap for filter pressure drop and aerosol test.
Easy filter change and cleaning of the diffuser and ductwork through open able diffuser panel. Integral guides shall enable exact positioning of the filter to ensure complete thigness.
HEPA filter with aluminium frame and cold moulded polyurethane or gel gasket according to EN 1822 is supplied with individual test certificate (H14).
Halton DHN
HEPA Nozzle diffuser
- Radial or swirl air supply through adjustable nozzle
- Available for supply and exhaust
- Suitable for integrated ceiling and wall installation
- A measurement access through the diffuser plenum for pressure measurement and aerosol test
- Easy filter change and cleaning through the openable diffuser panel
- Reduced installation space requirement due to low unit height
- Easy installation with fixing brackets
- Sizes 595 and 670 adapted for installation in modular suspended ceilings
- Filters E10, H13 and H14 available as standard
- Powder coated finishing, standard colour RAL9010
Accessories
- E10 and H13 with foamed polyurethane gasket
- H14 with foamed polyurthane or gel gasket
- Pre-filter G4 for exhaust applications
- Filters do not include to the diffuser delivery, to be ordered separately
Dimensions ▲
Halton DHN, top connection - circular (D=1)
DHN | ØD | W | H | K | K1 | K2 | P |
365-1 | 159 | 365 | 210 | 336 | 320 | 392 | 27 |
595-1 | 199 | 595 | 210 | 554 | 473 | 545 | 33 |
670-1 | 314 | 670 | 210 | 642 | 625 | 697 | 39 |
Halton DHN, top connection - circular (D=1)
DHN | ØD | W | P | K | M |
975-1 | 314 | 670 | 975 | 955 | 646 |
1280-1 | 399 | 670 | 1280 | 1260 | 646 |
Halton DHN, side connection - circular (D=2)
DHN | ØD | W | H | H1 | K | K1 | K2 |
365-2 | 159 | 365 | 360 | 252 | 336 | 320 | 392 |
595-2 | 199 | 595 | 400 | 272 | 554 | 473 | 545 |
670-2 | 249 | 670 | 450 | 297 | 642 | 625 | 697 |
Halton DHN, side connection - rectangular (D=3)
DHN | L | W | K | K1 | K2 |
365-3 | 199 | 365 | 336 | 320 | 392 |
595-3 | 399 | 595 | 554 | 473 | 545 |
670-3 | 499 | 670 | 641 | 625 | 697 |
Material ▲
Part | Material | Note |
Casing | Galvanised steel | |
Front panel | Steel | |
Nozzles | Polyacetal (POM) | Colour alternatives: |
Coupling sleeve | Galvanised steel | |
Filter brackets | Acid proof or galvanised steel | |
Guide pins | Polyethylene terephthalate (PET) | |
Fixing brackets | Galvanised steel | |
Finishing | Polyester painting, white (RAL 9010) | Special colours available |
Function ▲
Air is filtered and supplied radially into the space or exhausted through the front panel of the unit.
Supply air pattern can freely be directed in up to four directions or alternatively radially as swirl jet.
Filters ▲
Laminar flow filters, class E10, H13 and H14
Specification
- Strong frame and construction with steel protection grid
- Filters available in classes E10, H13 and H14
- Aluminium frame, foamed polyurethane or gel gasket
- Protection screens composed of stretched steel grid with white painting
Material
Part | Material |
Filter media | Folded class fibre paper |
Frame | Aluminium |
Gasket | Polyurethane or gel |
Operating range
- Continuous operating temperature 80 0C
- Relative humidity max. 100 %
- Recommended maximum final pressure drop 250 Pa
- The nominal flow rate is the recommended maximum, othewise the efficiency might reduce
Dimensions
E10, H13 and H14 with polyurethane gasket
Filter | W | H | D |
CLP-LF-AF-305-305-68 ... | 305 | 305 | 68 |
CLP-LF-AF-457-457-68 ... | 457 | 457 | 68 |
CLP-LF-AF-610-610-68 ... | 610 | 610 | 68 |
CLP-LF-AF-610-915-68 ... | 610 | 915 | 68 |
CLP-LF-AF-610-1220-68 ... | 610 | 1220 | 68 |
H14 with gel gasket
Filter | W | H | D |
CLP-LF-AF-305-305-78 ... | 305 | 305 | 78 |
CLP-LF-AF-457-457-78 ... | 457 | 457 | 78 |
CLP-LF-AF-610-610-78 ... | 610 | 610 | 78 |
CLP-LF-AF-610-915-78 ... | 610 | 915 | 78 |
CLP-LF-AF-610-1220-78 ... | 610 | 1220 | 78 |
Filter selection
Technical values
Airflow rate is based on face velocity of 0,45 m/s. This nominal flow rate should not exceed.
Coarse panel filter, class G4
Specification
- Progressive thermally smoothened synthetic polyester having high dust holding capacity and high constancy for humidity
- The filter media is framed by a rigid plastic frame, which makes filters completely incinerable.
- Glueable seal provided with filter delivery
Material
Part | Material |
Filter media | Polyester fibre |
Frame | Plastic |
Sealant | Foamed plastic |
Operating range
- Maximum operating temperature 80 0C
- Relative humidity max. 100 %
- Final pressure drop recommended for filter replacement 200 Pa
- Initial efficiency (2 µm, 1700 m3/h) 50 %
Dimensions
Filter | W | H | D |
CL-KSM-300x300x25-G4-S | 300 | 300 | 25 |
CL-KSM-455x455x25-G4-S | 455 | 455 | 25 |
CL-KSM-610x610x25-G4-S | 610 | 610 | 25 |
CL-KSM-455x610x25-G4-S | 455 | 610 | 25 |
CL-KSM-605x610x25-G4-S | 605 | 610 | 25 |
Filter dimensions are without gasket.
Filter selection
Installation ▲
1. Front panel
2. Filter
3. Plenum
4. Fixing brackets
The diffuser is connected directly to the duct by screwing or by riveting. The connection is sealed as leakproof with an appropriate method.
The diffuser is installed either fast into or hanged from the ceiling with M6 (recommended minimum) drop rods using fixing brackets. Alternatively the diffuser is installed fast to the wall construction.
It will not be allowed to drill or make any holes to the diffuser plenum.
Open the front panel be gently pulling from the openings in the front panel. Front panel will hang from the hinges. Detach the panel from the hinges.
Clean the diffuser plenum before the filter installation.
Install the filter into diffuser. The guide pins ensure the exact location of the filter. Turn or slide the brackets below the filter and tighten them evenly.
Scan the filter for bypass leakages and correct the tightness, if necessary.
Reattach the front panel by pushing it until the springs lock.
Adjustment ▲
The airflow adjustment and shut off will be made with PTS/A damper in the ductwork (tightness class 4 EN 1751). The pressure drop of the clean filter can be used as a reference for airflow rate with a reasonable accuracy. If there is no measurement unit available, Halton MSA or MSD may be used as measurement unit.
Constant or variable airflow and shutt off
The airflow is adjusted with the aid of electrical airflow management damper Halton HFB/G in the ductwork. Depending on the application the damper is ordered either with constant or variable air volume settings. See details of ordering from Halton HFB documentation.
Servicing ▲
Close the airflow with the shut off damper.
Detach the front panel by gently pulling from the openings in the front panel. The front panel can also be removed to further ease the filter change.
Remove the filter from the diffuser box by unlocking the brackets and turning or sliding the fasteners to the side.
Clean carefully the diffuser and housing with a suitable method.
Install the new filter and lock it with the fasteners and tighten the screws.
Scan the filter for bypass leakages and correct the tightness, if necessary.
Reattach the front panel by pushing it until the springs lock.
Specification ▲
Halton terminal diffuser DHN with HEPA filter for hospital and clean room environments to be installed flush to the ceiling or to the wall. Air is supplied through individually adjustable nozzles.
Nominal size 595 and 670 adapted for installation in modular suspended ceiling. Diffuser frame (size 595) adapted to suite different ceiling types. The diffuser is installed either fast into ceiling/wall or hanged from the ceiling using movable fixing parts.
Diffuser casing is made of galvanized steel and powder painted. The inside of the diffuser is smooth to enable easy cleaning and free from grooves to prevent collection of impurities. Plenum is equipped with an internal measurement tap for filter pressure drop and aerosol test.
Easy filter change and cleaning of the diffuser and ductwork through open able diffuser panel. Integral guides shall enable exact positioning of the filter to ensure complete thigness.
HEPA filter with aluminium frame and cold moulded polyurethane or gel gasket according to EN 1822 is supplied with individual test certificate (H14).
Order code ▲
DHN-A-D; CO-IO-MA-ZT
A = Diffuser size
365, 595, 670, 975, 1280
D = Duct connection
1 Top connection, circular (available in all sizes)
2 Side connection, circular (sizes 365, 595 and 670)
3 Side connection, rectangular (sizes 365, 595 and 670)
Other Options and Accessories
CO = Colour
W White (RAL 9010)
X Special colour
IO = Ceiling type installation option
NA Standard T-profile (for all sizes)
DC Clip-In (Dampa) ceiling (only for size 595)
MA = Material
CS Galvanised steel
ZT = Tailored product
N No
Y Yes
Related Products
Laminar flow filter
CLP-LF-AL-457-457-68-0-E11-GF-P
Coarse panel filter
CL-KSM-455-455-25-G4-S
Code Example
DHN-595-1, CO=W, IO=NA, MA=CS, ZT=N
Downloads & Media
Halton DHN - fr | Type Datasheet | Language French (France) | Size 1.5 MB |
Halton DHN - ru | Type Datasheet | Language Russian (Russia) | Size 1.4 MB |
Halton DHN - uk | Type Datasheet | Language English (United Kingdom) | Size 1.4 MB |