Skip to content

Product / URH

URH 圆形排风口

设计美观且便于调节。

Request a Quote

概述

  • 排风口
  • 安装在墙壁或吊顶上
  • 可调节气流
  • 可测量流量
  • 安装时可使用也可以不使用独立的安装架

Dimensions and weight

 

NS

ØW

H

ØD

100 140 13 98
125 165 13 122
160 200 13 158
200 251 13 198

Weight

NS

kg

100 0.3
125 0.4
160 0.6
200 0.8

Material

Part

Material

Note

Collar Steel
Central cone Steel
Gasket Polyurethane
Installation frame Galvanised steel Gasket of rubber compound
Protection ring Steel
Finishing Painted
white (RAL 9003)
Special colours available

Accessories

Accessory

Code

Description

Cover plate CS For protection of the surfaces from
smudging and for directing the air jet
in a grid-structured ceiling
Extension part EP Extension part for detaching the valve
from the surface/
standard height 50 mm
Installation frame LF Installation frame without gasket/
height 50 mm
Installation frame GF Installation frame with gasket/
height 50 mm
Installation frame DF Installation frame with duct
dimensions can be installed directly to duct
parts such as bending or T-branch etc

 

 
Fig.1. Cover plate (CS)                               Fig.2. Extensions part (EP)

 
Fig.3. Installation frame (LF)                        Fig.4. Installation frame (GF)


Fig.5.  Installation frame (DF)

Function

The valve throttles the exhaust airflow and attenuates the duct noise. The pressure drop is dependant on the position of the central cone. The desired exhaust airflow rate is adjusted during the balancing of the airflows in a ductwork system. After the adjustment the valve is locked at the required adjustment position.

Installation

The Halton URH exhaust valve is mounted with the aid of a separate installation frame LF, GF or DF. Push the installation frame into the duct and fix it. Push the valve into the installation frame and turn until it is firmly attached.
Alternatively model URH/B can be installed directly into a duct without an installation frame.

Installation with protection ring (CS)

 

NS

Ø W2

100 290
125 315
160 350
200 400

Adjustment

The Halton URH valve is adjusted by rotating the central cone. Measure the opening (A) position (in mm) of the central cone. Set a probe inside the valve and measure the differential pressure with a manometer. The airflow rate is calculated using the formula below. After the adjustment, lock the central cone with the locking nut.
 

                                     

 

A
URH Ø 100

k
URH Ø 100

 

A
URH Ø 125 

k
URH Ø 125 

 

A
URH Ø 160

k
URH Ø 160

 

A
URH Ø 200

k
URH Ø 200

  -15 0,43   -15 0,65   -12 1,16   3 1,78
  -12 0,63   -12 0,92   -9 1,51   6 2,46
  -9 0,83   -9 1,22   -6 1,9   9 3,24
  -6 1,02   -6 1,53   -3 2,31   12 3,97
  -3 1,22   -3 1,84   0 2,75   15 4,69
  0 1,42   0 2,17   3 3,25   20 5,88
  3 1,65   3 2,52   6 3,73   25 6,95
  6 1,88   6 2,83   9 4,22      
  9 2,11   9 3,14   12 4,67      
  12 2,33   12 3,46   15 5,12      
        15 3,77   18 5,58      

 

Servicing

Code description
1.   Central cone
2.   Locking nut
3.   Sleeve

Loosen the valve from the ductwork by turning counter-clockwise. Note the adjusted opening position of the central cone.
Wipe the parts with a damp cloth, instead of immersing in water. Reassemble valve in reverse order after cleaning.

Specification

The  exhaust valve shall have an adjustable central cone and sleeve made of painted steel, with a white (RAL 9003) standard colour. The valve shall be fitted with a galvanised steel installation frame. The installation frame shall incorporate a sealing gasket.

Alternative: The valve shall be fixed with springs directly into a duct.

The opening position of the central cone shall be adjusted during balancing in order to achieve required pressure loss and airflow rate. After balancing the central cone shall be locked to the selected adjustment position.

Order Code

URH/S-D

S = Model
       A    Standard
       B    With fastening springs

D = Connection size
       100, 125, 160, 200

Other options and accessories

CO = Colour
          SW    White (RAL 9003)
          X        Special colour (RAL xxxx)

ZT  = Tailored product
     
     N     No
          Y     Yes (ETO)

Sub products

          CS    Cover plate (ULA)
          EP    Extension part
          DF     Installation frame for duct parts
          GF    Installation frame with gasket
          LF    Installation frame without gasket

Code example

         URH/A-100, CO=SW, ZT=N

Downloads

Contact Us

"*" indicates required fields

Hidden
Marketing Communications Consent
Max. file size: 128 MB.
This field is for validation purposes and should be left unchanged.