Skip to content

Product / ZRE

Halton Zen Rectangular (ZRE) – Displacement ventilation unit

Rectangular displacement unit, excellent for general use.

  • Capacity for wide supply airflow range
  • Low velocity air is supplied horizontally at the floor level

 

Request a Quote

Overview

  • Capable of a large supply airflow range
  • Uniform supply air distribution is achieved through small perforations, providing optimal conditions in the immediate proximity of the diffuser.
  • Low velocity air is supplied horisontally at the floor level.
  • The unit can also be installed flush with the wall.
  • Ceiling installation available as tailored solution. Please contact sales..
  • The detachable front panel and metallic internal structure enable cleaning of the unit and ductwork.
  • Circular or rectangular duct connections available, with integrated rubber gasket at the top/bottom, or circular connections on the side or back.

Product models and accessories

  • Optional duct connection locations
  • Stainless steel (AISI 316L) design
  • Model with thick front panel (1.5 mm)
  • Duct cover
  • Installation base
  • Installation frame

Selection

Quick selection


Fig.1.  Halton Zen Rectangular, top connection


Fig.2.  Halton Zen Rectangular, left and right connection


Fig.3.  Halton Zen Rectangular, back connection

Dimensions and weight

NS W H W1 H1 K K1 ØD
125 550 540 275 125 240 110 124
160 550 540 275 125 240 110 159
200 550 1140 275 145 280 130 199
250 660 1350 330 170 330 155 249
315 830 1600 415 200 400 188 314
400 950 2000 475 245 480 230 399
  *)1000×300 1150 2000 575 380 180 998×298

*) Size 1000×300 available only with top connection

  • AB/ZRE  installation base:
    Height = 100 mm
  • SB/ZRE  installation base, high model:
    Height = 200 mm, W=W+120, K=K+60

Weight

NS kg
125 10.7
160 10.7
200 20.0
250 28.3
315 41.0
400 58.0
1000×300 62.4

Material

Part Material Note
Front panel Perforated galvanised steel Stainless steel (AISI 316L)
as option
Polyester-epoxy painted
White
(RAL 9003 / 30% gloss)
Special colours available
Casing Galvanised steel Stainless steel (AISI 316L)
as option
Flow equalisation
element
Galvanised steel
Pressure measurement
pipe
Plastic
Spigot Galvanised steel
Gasket Rubber compound
Duct cover Galvanised steel
Polyester-epoxy painted
White
(RAL 9003 / 30% gloss)
Special colours available
Installation base Galvanised steel
Polyester-epoxy painted
White
(RAL 9003 / 30% gloss)
Special colours available
Cover list Galvanised steel
Polyester-epoxy painted
White
(RAL 9003 / 30% gloss)
Special colours available

Accessories

Accessory Code Description  Note
Duct cover (1) DC Standard lengths
500 / 1000 / 1500 / 2000 mm
 Installation base (2) AB Standard height 100 mm
Installation base SB Standard height 200 mm /
Dimensions = unit size + 60 mm
High (store) model
Cover list CL Cover list for fixing into wall or ceiling

Product Models

  • Duct cover (DC) made of perforated steel (same material as ZRE unit)
  • Construction made of stainless steel (AISI 316L)
  • Thicker front panel (1.5 mm)
  • Optional duct connection sides (left, right or back – see images below)
    Note: Size 1000×300 available only with top connection


Fig.1. 
Connection from top (ZRE/T)


Fig.2. 
Connection from left (ZRE/L)


Fig.3. 
Connection from right (ZRE/R)


Fig.4.  Connection from back (ZRE/B)

Function

Air is supplied into the space uniformly through the front panel of Halton Zen Rectagular, generally at a slightly lower temperature than the room air. The supply air flows down to the floor level, before gradually pervading the occupied zone at a low velocity. Finally the convection of warm surfaces causes the air to rise out of the occupied zone. The low velocity flow pattern is directed forwards.

The non-clogging unit can be easily opened and cleaned.

Halton PRA or Halton PTS/C can be used as an airflow adjustment damper in round duct sections. The safety distance for reliable air flow measurement from the displacement unit is 5 duct dimensions between displacement unit and air flow adjustment damper.
If air flow adjustment damper is installed closer to the displacement unit (minimum distance about 3 duct dimensions), supply air throw pattern is correct, but air flow measurement result will not be accurate. When installing air flow adjustment damper close to the displacement unit (minimum 3xD), attenuator could be needed between the damper and the displacement unit.

Note: The flow pattern data has been defined for a floor level installation.

Installation

Perform the installation for Halton Zen Rectangular in the following order:
A)   Installation without base:
Fix mounting brackets(4 places) to the unit (1).
Position the unit (2) against the wall and secure  with mounting brackets
(included in delivery).

Installation with  base:
Fix the base (6) onto the floor and fix the unit  (2) onto that.
Secure with mounting brackets on top (1) (2 places)

B)    Fix duct cover sides (4) onto the wall between the unit and ceiling with
screws (not included in delivery) through cover.

C)    After installation of the ductwork, install the front plate of the duct cover (5).

D)    When multiple sections of duct covers are used, secure them with screws
(not included in delivery).

E)    Install front plate of the low velocity unit (6).

Ceiling installation available as tailored solution. Please contact sales.

Adjustment

The supply flow rate is determined by measuring the differential pressure from the measurement nipple with a manometer.Use a measurement probe thin enough fit into the nipple. Then use tape or another gasket to create a seal in the nipple in order to get an accurate reading .

The flow rate is calculated by using the formula below:

The values of k factor for formula
(D = duct diameter; L/R, T, B = location of duct connection)

D k – L/R k – T k – B
125 10.9 11.1  12.1
160 15.6 16.2 17.1
200 27.3 26.9 29.1
250 44.3 42.9 47.6
315 67.9 66.1 74.2
400 105.7 100.7 118.1
1000X300 166.3

Servicing

Code description
1.    Front panel
2.    Casing

Open the front panel (1) by carefully pulling the spring connections out.

If required, the flow equalization plate can be detached.

Wipe the parts with a damp cloth. Do not immerse in water.

Reassemble after cleaning in reverse order.

Specification

The Halton Zen Rectangular displacement ventilation supply unit is made of galvanised steel, polyester-epoxy-painted with a white (RAL 9003) colour.

The unit has a robust maintenance-free, non-clogging design.
The unit is comprised of a detachable, perforated front panel, an internal flow equalization plate, and casing.

The unit has a circular or rectangular duct connection on at the top, or a circular connection on the left/right side or back depending on where the unit is located.

Mounting brackets are included in the delivery, screws not.

Options

The unit is equipped with a duct cover and/or installation base, where required.

The front panel of the unit is available of 1.5mm thick galvanised steel for demanding spaces.

Order Code

ZRE/S-D; MA-TP-CO-ZT

S = Location of duct connection
T      Top
L       Left
R      Right
B      Back

D = Size of duct connection (mm)
125, 160, 200, 250, 315, 400
1000 x 300 (only top connection)

Other options and accessories

MA = Material
CS         Steel
AS         Stainless steel (AISI 316L)

TP = Front panel thickness 1.5 mm
N            No
Y            Yes

CO = Colour
SW      Signal white (RAL 9003)
X          Special colour (RAL xxxx)

ZT  = Tailored product
N            No
Y            Yes  (ETO)

Sub products

DC         Duct cover
AB          Installation base (standard)
SB          Installation base (high, store)
CL          Cover list

Code example

ZRE/T-160, MA=CS, TP=N, CO=SW, ZT=N

Downloads

  • Halton Zen Rectangular (ZRE) – Displacement ventilation unit

    Data

    de

    Shape 2
Contact Us

"*" indicates required fields

Hidden
Marketing Communications Consent
Max. file size: 128 MB.