Skip to content

Product / DFA

Halton DFA – Square conical diffuser

Easy to clean and maintain due to many slots.

  • Suitable for horisontal supply and exhaust
  • Openable cone module enables cleaning of the diffuser and ductwork
Request a Quote

Overview

  • Suitable for horisontal supply and exhaust
  • Circular duct connection with rubber gasket
  • Openable cone module enables cleaning of the diffuser and ductwork
  • Lightweight aluminum material

Accessories

  • Balancing plenum with measurement and adjustment functions

Dimensions

NS W W1 H ØD
125 295 150 63 124
160 370 225 63 159
250-445 445 300 63 249
250-520 520 375 63 249
315 520 375 63 314
400 595 450 100 399

Material

Part Material Finishing Note
Frame Aluminium Polyester-painted,
White (RAL 9003/
30% gloss)
Epoxy-painting
(100%) available
Front panel Aluminium Polyester-painted,
White (RAL 9003/
30% gloss)
Epoxy-painting
(100%) available
Perforated plate Galvanised steel 45 % perforation
Plenum / spigot Galvanised steel

Accessories

Accessory Code Description
Balancing plenum TRI/N For balancing, equalizing the airflow
(with airflow measurement and adjustment module)
Sound attenuation IN Polyester fibre ( Halton TRI)
Airflow measurement
and adjustment module
MSM For supply installation


Fig.1.  Halton DFA diffuser with Halton TRI plenum

Function

Air is supplied horizontally into the space through the slots of the conical front panel. Supply air mixes with room air in the vicinity of the diffuser.

The fixed cones of the diffuser are designed to ensure that the supply air flows along the ceiling. The Halton  DFA diffuser can also be used as an exhaust unit.

Installation

Code description
1.  Front panel
2.  Frame
3.  Perforated plate

The diffuser is connected either directly to the duct or using a Halton TRI balancing plenum.

Installation with Halton TRI plenum

ØD ØD1 TRI W2 H1
125 100 100-125 235 272-322
160 125 125-160 310 302-352
250-445 160 160-250 385 342-392
250-520 200 200-250 460 392-442
315 250 250-315 460 456-506
400 250 250-400 535 456-506

The technical performance for the combination of supply air diffuser and Halton TRI plenum is presented separately for the two different installations.

Duct installation

When the Halton DFA diffuser is installed without a Halton TRI balancing plenum, it is recommended that the diffuser be connected to ductwork using a straight connection duct of minimum length 3xD upstream of the diffuser.

Adjustment

In order to enable airflow adjustment and measurement of airflow rate, it is recommended that the diffuser be connected to the Halton TRI balancing plenum equipped with the MSM module.
The supply flow rate is adjusted by using the measurement and adjustment module MSM.

Detach the front panel and pass the tubes and control spindle through the diffuser.
Measure the differential pressure using a manometer. The flow rate is calculated using the formula below.

Adjust the airflow rate by rotating the control spindle until the desired setting is achieved.
Lock the damper position with a screw.

Replace the tubes and spindle into the plenum and reattach the front panel.
The  k factor for installations with different safety distances
(D= duct diameter)

TRI >6xD min 3xD
100 6.0 7.5
125 9.9 12.6
160 16.9 21.9
200 28.3 31.0
250 47.9 51.5
315 78.6

Servicing

Remove the front panel (central cones) by gently drawing out the central part.

Detach the perforated plate from the supply air section and sleeve.

Clean the parts by wiping them with a damp cloth.
Push the perforated plate back into place.

Push the front panel back into place so that the springs lock.

Option: with balancing plenum Halton TRI + MSM

Remove the measurement and adjustment module by gently pulling the shaft (not the control spindle).
Wipe the parts with a damp cloth, instead of immersing in water.

Reassemble the measurement and adjustment module by pushing in the shaft until the module meets the stopper.
Push the front panel back into place so that the clips lock.

Specification

The diffuser is made of extruded aluminium, anodised or polyester-painted with a white (RAL 9003) standard colour.

The bevel angles of the outer frame and central cone are welded so that the joints are almost invisible.

The diffuser has a galvanised steel transition to provide for circular duct connection. The spigot has a sealing gasket for airtight duct connection.

The diffuser is connected to the ductwork using a balancing plenum, which comprises polyester fibre with a washable surface as sound attenuation material.

The plenum is equipped with an airflow measurement and adjustment module.
The front panel of the diffuser is detachable in order to provide access to the measurement and adjustment module in the plenum.

Order Code

DFA-D-A; FI-CO-ZT

D = Connection size (mm)
125, 160, 250, 315, 400

A = Diffuser size (mm)
295, 370, 450, 520, 595

Other options and accessories

FI  = Finishing
PN     Painted

CO = Colour
SW      Signal white (RAL 9003)
X          Special colour

ZT  = Tailored product
N        No
Y        Yes (ETO)

Sub products

TRI     Plenum

Code example

DFA-125-295, FI=PN, CO=SW, ZT=N

Downloads

  • Halton DFA – Square conical diffuser

    Data

    en

    Shape 2
  • Halton DFA – Neliömäinen kartiohajottaja

    Data

    fi

    Shape 2
  • Halton DFA – Diffuseur plafonnier multidirectionnel

    Data

    fr

    Shape 2
  • Halton DFA – Kvadratisk konspridare

    Data

    se

    Shape 2
  • Halton DFA – fr

    Data

    fr_FR
    Shape 2
Contact Us
  • Hidden
  • Max. file size: 64 MB.