TCM - Conical diffuser

Circular conical diffuser for ceiling installation

Ideal for warm spaces due to the cooling applications.

  • Suitable for horisontal supply and exhaust
  • Suitable for cooling applications with supply/room air temperature difference as low as -12 °C
  • Integrated or suspended ceiling installation
  • Circular duct connection with rubber gasket
  • Detachable cone module, enabling the cleaning of the diffuser and ductwork

Product models and Accessories

  • Models integrated in a panel for installation in modular suspended ceilings with dimension options of 450x450, 600x600 or 675x675 mm
  • Plenum options with measurement and adjustment functions
  • Measurement and adjustment module

The diffuser comprises several cones, made of epoxy-painted steel with a white (RAL 9010) or grey (RAL7004) standard colour.

The diffuser is suitable for exposed installation or installation flush to the ceiling.

The diffuser is connected to the ductwork using a Halton TRI balancing plenum, which utilises polyester fibre with a washable surface as sound attenuation material.

Option

The diffuser is connected to the ductwork using a Halton PLC plenum, which utilises mineral wool as sound attenuation material.

The plenum comprises an airflow measurement and adjustment module.
The diffuser is suitable for installation in 450x450 mm, 600x600 mm and 675x675 mm false ceilings.
The conical central core is removable.

The supply air pattern is radial in an angle of 360 degrees.

Halton TCM

Circular conical ceiling diffuser


 

  • Suitable for horisontal supply and exhaust
  • Suitable for cooling applications with supply/room air temperature difference as low as -12 °C
  • Integrated or suspended ceiling installation
  • Circular duct connection with rubber gasket
  • Detachable cone module, enabling the cleaning of the diffuser and ductwork

Product models and Accessories

  • Models integrated in a panel for installation in modular suspended ceilings with dimension options of 450x450, 600x600 or 675x675 mm
  • Plenum options with measurement and adjustment functions
  • Measurement and adjustment module

Dimensions

NS  W  H  H1  ØD 
100  330 80 17 99
125  330 80 17 124
160  330 73 17 159
200  457 88 22 199
250  610 110 27 249
315  610 95 27 314
355  863 139 35 354
400  863 129 35 399
450  863 121 35 449
560  1220 175 46 558
630  1220 163 46 628
800  1524 190 57 798
1000  1727 124 127 998

Material

 Part  Material  Finishing
 Diffuser  Steel  Epoxy-painted
 White (RAL 9010) or
 Grey RAL 7004) /
 50% gloss
 Plenum  Galvanised steel  

Accessories

 Accessory Code  Description
 Balancing plenum with airflow
 measurement and adjustment unit
TRI/N  For balancing,
 equalising the airflow
 Plenum PLC  Plenum for duct connection
 (with or without insulation)
 Sound attenuation IN  Polyester fibre as sound attenuation
 material in Halton TRI plenum.
 Mineral wool as sound attenuation
 material in Halton PLC plenum.
 Airflow measurement
 and adjustment unit
MSM  For supply installation
 Airflow adjustment unit LD  Circular galvanised steel unit for airflow
 adjustment (inside the coupling sleeve)
 Airflow adjustment damper DD  Circular galvanised steel blade damper
 for flow adjustment (inside the coupling
 sleeve)

Product models

 Product model Code  Description
 Diffuser integrated in front panel,
 600x600 mm
TCM/B  Sizes 100, 125, 160, 200, 250 and 315
 are available integrated in a steel
 panel for installation in a modular
 600x600 mm suspended ceiling.
 The external dimensions of the
 front panel are 595x595 mm.
 Diffuser integrated in front panel,
 450x450 mm
TCM/C  Sizes 100, 125 and 160 are available
 integrated in a steel panel for
 installation in a modular 450x450 mm
 suspended ceiling.
 The external dimensions of the
 front panel are 445x445 mm.
 Diffuser integrated in front panel,
 670x670 mm
TCM/D  Sizes 100, 125, 160, 200, 250 and 315
 are available integrated in a steel
 panel for installation in a modular
 675x675 mm suspended ceiling.
 The external dimensions of the
 front panel are 670x670 mm.

Function

Supply air is divided into several jets through the cones.
The divergent sections of the diffuser create negative pressure below the diffuser so room air is induced into the supply air device. Room air and supply air mix.

This internal induction reduces temperature and the air velocity into the space.
The process is the same outside the diffuser between the supply and mixed room air, with external induction further reducing velocity and the temperature difference between supply and room air.
This effect reduces the flow disturbances.

The diffuser can also be used as an exhaust unit.

Installation

Code description
1.  TCM
2.  PLC plenum

The Halton TCM diffuser can be installed flush with a suspended ceiling or fully exposed in the space.
The diffuser is connected either directly to the duct or using a Halton PLC plenum or Halton TRI balancing plenum.
When it is connected directly to ductwork, a safety distance of minimum 3D upstream of the diffuser should be maintained.
 

Installation with plenum Halton TRI or PLC

 

TCM  ØD  TRI  H1  H2 
100  100 TRI-100-100 17 249...279
125  125 TRI-125-125 17 279...309
160  160 TRI-160-160 17 312...342
200  200 TRI-200-200 22 377...407
250  250 TRI-250-250 27 394...424
315  315 TRI-315-315 27 494...524


When the Halton TRI spigot is installed in the plenum, the H2 dimension can be reduced by 60 mm.

TCM  ØD  PLC  H1  H2 
355  355 PLC-355 27 604...634
400  400 PLC-400 35 584...614
450  450 PLC-450 35 786...816
560  560 PLC-560 46 840...870
630  630 PLC-630 46 823...853


Dimensions of ceiling opening
 

NS  ØW1 
100  266
125  266
160  266
200  406
250  533
315  533
355  787
400  787
450  787
560  1140
630  1140
800  1384
1000  1500

Adjustment

The airflow rate can be adjusted and measured only when the diffuser is installed.

In order to enable airflow adjustment and measurement of airflow rate, it is recommended that the diffuser be connected to a plenum equipped with the MSM module.
The supply flow rate is determined using measurement and adjustment module MSM.

Detach the conical central core and pass the tubes and control spindle through the diffuser.
Measure the differential pressure with a manometer. The flow rate is calculated using the formula below.

Adjust the airflow rate by rotating the control spindle until the desired setting is achieved.
Lock the damper position with a screw.
Replace the tubes and spindle in the plenum and push the conical central core back into place.

The k-factors for installations with different safety distances
(D= duct diameter)

 

PLC/TRI  >8xD  min 3xD 
125  9.9 12.6
160  16.9 21.9
200  28.3 31.0
250  47.9 51.5
315  78.6  

 

Airflow adjustment damper DD

The airflow rate is adjusted by turning the damper blades behind the diffuser with a screwdriver. The measurement is carried out when the diffuser is installed.

Servicing

Remove the conical central core by gently drawing it out by the central panel (simultaneously, a small pin on the inner side of the external cone is pushed and the assembly is turned clockwise, until it comes free).

Clean the parts by wiping them with a damp cloth.

Push the conical central core back into place so that the springs lock.
 

Option: with balancing plenum Halton TRI + MSM or PLC + MSM

Remove the measurement and adjustment module by gently pulling the shaft (not the control spindle).
Wipe the parts with a damp cloth, instead of immersing in water.

Reassemble the measurement and adjustment module by pushing the shaft until the module meets the stopper.

Push the conical central core back into place so that the pin locks.

Specification

The diffuser comprises several cones, made of epoxy-painted steel with a white (RAL 9010) or grey (RAL7004) standard colour.

The diffuser is suitable for exposed installation or installation flush to the ceiling.

The diffuser is connected to the ductwork using a Halton TRI balancing plenum, which utilises polyester fibre with a washable surface as sound attenuation material.

Option

The diffuser is connected to the ductwork using a Halton PLC plenum, which utilises mineral wool as sound attenuation material.

The plenum comprises an airflow measurement and adjustment module.
The diffuser is suitable for installation in 450x450 mm, 600x600 mm and 675x675 mm false ceilings.
The conical central core is removable.

The supply air pattern is radial in an angle of 360 degrees.

Order code

TCM-D; WS-CO-ZT

D = Connection size
      100, 125, 160, 200, 250, 315, 355, 400, 450, 560, 600, 630, 800, 1000

Other options and Accessories

WS = Width of suspended ceiling tile
          N        Standard
          450     450x450
          600     600x600
          675     675x675

CO = Colour
         W       White
         G        Grey

ZT = Tailored product
        N         No
        Y         Yes
 

Sub products

        PLC     Plenum (Ceiling Diffusers)
        TRI       Plenum (Diffusers)
         DD      Airflow adjustment damper
         LD      Airflow adjustment damper
 

Code example

          TCM-100, WS=N, CO=W, ZT=N

Downloads & Media

Halton TCM - gb
Type
Datasheet
Language
English (United Kingdom)
Size
797.4 kB
Halton TCM - fr
Type
Datasheet
Language
French (France)
Size
626.3 kB
Halton TCM - ru
Type
Datasheet
Language
Russian (Russia)
Size
827.7 kB
Halton TCM - se
Type
Datasheet
Language
Swedish (Sweden)
Size
797.7 kB
Halton TCM - dk
Type
Datasheet
Language
Danish (Denmark)
Size
797.7 kB
Halton TCM - fi
Type
Datasheet
Language
Finnish (Finland)
Size
796.8 kB
Halton TCM - nl
Type
Datasheet
Language
Dutch (Netherlands)
Size
793.2 kB